DUS360CR多功能感应器(有需要联系我们)
DUS360-CR 913703500709 替代DUS804C
DUS360-CR-DA 913703500809 替代DUS804C-Dali
DUS360CR Multifunction SensorLow profile 360° ceiling sensor
DUS360CR To reduce the risk of fire or electric shock, do not expose this device to rain or moisture. Installation, programming and maintenance must be carried out by qualified personnel. All local wiring and electrical regulations must be followed when installing device. Overview • 360º motion detection (PIR) – Detects presence or absence ofmotion and adjusts lights accordingly. • Low profile recessed flush mount • Segmented click-up bezel – Masks unused detection areas • Ambient light level detection (PE) – Allows accurate lightingcontrol and daylight harvesting. • Infrared Rx sensor – device enables system control via any RC5IR remote. Ceiling Mount Universal Sensor Read Instructions – We recommend that you read these instructions prior to commencement of installation. Check Connections – Ensure that all wiring terminals are securely connected. Mounting Location – For indoor use only. Select sensor locations as per user requirements. Note that the optimal locations for PIR and PE use may be different, requiring multiple sensors in the same area. Data Cable – Use screened, stranded RS485 data cable with three twisted pairs. Segregate from mains cables by at least 300mm. Connect devices in a ‘daisy chain’ configuration. A data cable that is connected to an energized device is live. Do not cut or terminate live data cables. Installation – Installation must be done in accordance to the local wiring code (or wiring rules). Installation of home and building automation and control systems shall comply with HD60364-4-41. Installation Steps 1. Fix the sensor to a 64 mm diameter circular hole in a firm section of the ceiling. The mounting position should adhere to the following guidelines: • Ceiling height should be between 2.1 m and 4.0 m. Optimum height is 2.4 m. • Position the sensor at least 1 m away from electrical lighting such as neon and fluorescent lights. • Avoid exposure to direct sunlight and heating/cooling sources. • Position the sensor where pedestrian traffic is likely to move through the detection zone. • Note that the sensor coverage area is rectangular, approximately 7.6 m x 5.4 m (at 2.4 m installation height). • The detection range above is specified for an ambient temperature of 25ºC. This range is reduced at higher temperatures. 2. If needed, pull out and rotate the masking bezel to block a 120º viewing angle. 3. Terminate the DyNet cable as indicated below. If terminated and powered correctly, the red indicator LED turns on for 5 seconds. DyNet Terminal 5-way pluggable screw terminal 1 x 2.5mm2 conductor size DyNet Network Supply RS485 12-24 VDC, 20mA max PIR sensor: Quad element pyroelectric Max detection range: 5 m Detection area: 7.4 m x 5.6 m (at 2.4m mounting height) Detection speed: 1 m/s Detection object: 700 mm x 250 mm Detection zones: 64 Activation indicator: LED PE cell:5000 lux (reflected) Automatic daylight harvesting mode Infrared Rx: RC5 Controls: Walk test / LED indicator Network sign-on button Compliance: CE, RCM Operating Conditions: Temperature: 0 to 45° C ambient Humidity: 0 to 90% non-condensing Storage & Transport: Temperature: -25 to 60° C ambient Humidity: 0 to 90% non-condensing Construction: ABS plastic enclosure Dimensions: 72 mm dia. x 41 mm (2.8” dia. x 1.6”) Packed Weight: TBA kg Installation Steps 1. Fix the sensor to a 64 mm diameter circular hole in a firm section of the ceiling. The mounting position should adhere to the following guidelines: • Ceiling height should be between 2.1 m and 4.0 m. Optimum height is 2.4 m. • Position the sensor at least 1 m away from electrical lighting such as neon and fluorescent lights. • Avoid exposure to direct sunlight and heating/cooling sources. • Position the sensor where pedestrian traffic is likely to move through the detection zone. • Note that the sensor coverage area is rectangular, approximately 7.6 m x 5.4 m (at 2.4 m installation height). • The detection range above is specified for an ambient temperature of 25ºC. This range is reduced at higher temperatures. 2. If needed, pull out and rotate the masking bezel to block a 120º viewing angle. 3. Terminate the DyNet cable as indicated below. If terminated and powered correctly, the red indicator LED turns on for 5 seconds. Recommended Cable Type Dynalite DYNET-STP-CABLE or equivalent shielded three twisted-pair cable. See datasheet for more information. Recommended Cable Color Coding Green/White Pair Paralleled for GND Orange/White Pair Paralleled for +12VDC Blue/White Pair Blue for DATA+ White for DATA- Brown/White Pair Spare, use for SHIELD on unshielded cables RS485 DyNet network DUS360CR Multifunction SensorLow profile 360° ceiling sensor The DUS360CR is a recess mountable 360 degree multifunction sensor that combines motion detection (PIR), Infrared remote control reception (IR) and ambient light level detection (PE) into one device in applications such as offices, lecture theaters and homes. 72mm2.8in63mm2.5in41mm1.6in39mm1.5in For detailed product information, please refer to the product information pages at www.philips.com/dynalite and follow the links. • Motion detection feature — Detects thepresence or absence of motion and adjusts lightsaccordingly.• Segmented click-up bezel — Surrounds themotion sensor element and enables a portionof the sensing field to be masked. This preventsnuisance detection from adjacent doorways orcorridors.• Ambient light level detection and daylightharvesting — In applications where it is criticalto maintain precise light, the PE function readsambient levels and adjusts artificial light accordingly.• Infrared receive capability — Manually adjust lightlevels using a hand-held remote control, via theinbuilt IR receive sensor of the DUS360CR.• Daylight Harvesting mode — Delivers automaticenergy savings. DRAFT DUS360CR Oct-15 Specifications Due to continuous improvements and innovations, specifications may change without notice. Item Specification Details Hardware Motion Detector Standard sensitivity Maximum detection range: 5 m Detection area: 7.4 m x 5.6 m rectangular (at a height of 2.4 m) Detection speed: 1.0 m/s Detection object: 700 mm x 250 mm Detection zones: 64 LED activation indicator Sensor: Quad element pyroelectric PE Cell Range5000 lux Automatic ‘Daylight Harvesting’ mode Infrared Remote Control Receiver Range up to 6 m LED activation indicator Supports RC5 IR remote control Terminals Standard: 5 way terminal strip, 1 x 2.5 mm² max conductor size Controls Walk test/IR received LED indicator Tamper switch Network Control Inputs/Outputs One RS-485 DyNet serial port DUS360CR-DA ONLY: DIP switch logical area assignment DyNet Network Supply 12-24 VDC, 20 mA max Configurations All functions remotely programmable Physical Dimensions (H x W x D) 72 mm dia. x 64 mm (2.8” dia. x 2.5”) Packed Weight ?.?? kg TBA Construction ABS plastic enclosure RAL # (TBA) Operating Conditions Temperature: 0 to 45° C ambient Humidity: 0 to 90% non-condensing Storage & Transport Temperature: -25 to 60° C ambient Humidity: 0 to 90% non-condensing Mounting Substrate Thickness 3 - 25mm (0.12 - 1”) Certification Certification CE, RCM Options & Ordering Standard Product Dipswitch DUS360CR |